27650
27657
CT Chest and Abd Pelvis Ped w/IVcon IMG14096
Machine Model: Canon AQ Prime
Generated:
2021-04-20 10:32:07
IV Contrast See Below using Hand or Injector See IV Guidelines
for other access lines.
IV Saline NA
Oral Contrast TBD by MD or Radiologist
Water NA
Contrast amount determined by weight and renal function.
Special Instructions: Above lung apices to lesser trochanter
Scanogram: AP/Lateral
Landmark: Apices
A Venous
Scan Start Apices
Scan Stop Lesser Trochanter
Patient Position Supine
Scan Direction Craniocaudal
Scan Mode Helical
Scan Range If Volume NA
Scan Delay 60 seconds
Reconstruction 1 Thickness x Spacing 1 mm x 1 mm
Algorithm Ped Body
FOV 24 cm
Reconstruction 2 Thickness x Spacing 1 mm x 1 mm
Algorithm Lung STD
FOV RIB to RIB
FC 18
kVp See Chart Below Based on Weight
Scan FOV Patient largest + 2CM
Pitch Standard
mA modulated mA
Rotation Time .5 sec
Detector Rows 0.5 mm x 64 mm
Indications: FUO (fever of unknown origin) in immunocompromised host , PTLPD - include neck , aplastic anemia and neutropenia , infection , lymphoma - include neck , malignant tumors and chemotherapy f/u , opsiclonus/myoclonus , trauma , vasculopathy .
15KG-30KG 0.35 Rotation Time
31KG - 61KG+ 0.5 Rotation Time