19476
19481
CT Larynx / Hypopharynx Dtl w/IVcon IMG14066
Machine Model: Canon AQ 16
Generated:
2021-05-10 13:13:23
IV Contrast 0.8 ml/sec using 24 g PIV Minimum See IV Guidelines
for other access lines.
IV Saline NA
Oral Contrast NA
Water NA
Contrast amount determined by weight and renal function.
Special Instructions: IOML perpendicular to table top
Scanogram: Lateral / AP
Landmark: 2 cm below Carina
A Venous
Scan Start Above Sella
Scan Stop 2 cm below Carina
Patient Position Supine
Scan Direction Craniocaudal
Scan Mode Helical
Scan Range If Volume NA
Scan Delay 90 seconds
Reconstruction 1 Thickness x Spacing 1 mm x 1 mm
Algorithm Body STD
FOV 18 cm
Reconstruction 2 Thickness x Spacing .5 mm x .3 mm
Algorithm Bone
FOV 18 cm
FC 8
kVp 120 kVp
Scan FOV 18 cm
Pitch Standard
mA modulated mA
Rotation Time .5 sec
Detector Rows 1 mm x 16 mm
Indications: acute trauma involving the larynx or hypopharynx , benign masses of the larynx and hypopharynx , dysphagia , glottic and subglottic malignancy , inflammatory disease of the larynx and hypopharynx , larynx cancer , malignant tumors - glottic (true vocal cord) and subglottic , malignant tumors - hypopharynx - including pyriform sinus, posterior pharyngeal wall and post cricoid , malignant tumors - supraglottic - including the false vocal cord, aryepiglottic fold, epiglottis , supraglottic malignancy , thyroglossal duct remnants (cysts and others) .
No additional information.