11552
11553
CT Abdomen Pelvis w/IVcon IMG12098
Machine Model: Canon Genesis 640
Generated:
2022-10-04 08:19:13
IV Contrast 2 ml/sec using 22 g PIV Minimum See IV Guidelines
for other access lines.
IV Saline NA
Oral Contrast 4-8 oz or 944 ml
Water NA
Contrast amount determined by weight and renal function.
Special Instructions: Dome of Diaphragm to Lesser Trochanter
Scanogram: AP/Lateral
Landmark: Dome of Diaphram
A Venous
Scan Start Dome of Diaphram
Scan Stop Lesser Trochanter
Patient Position Supine
Scan Direction Craniocaudal
Scan Mode Helical
Scan Range If Volume NA
Scan Delay 70 seconds
Reconstruction 1 Thickness x Spacing 1 mm x 1 mm
Algorithm Body STD
FOV 40 cm
FC 18
kVp Auto* kVp
Scan FOV Patient Largest + 4CM
Pitch Standard
mA modulated mA
Rotation Time .5 sec
Detector Rows 0.5 mm x 80 mm
Indications: abdominal abscess evaluation , abdominal hernia , abdominal pain , appendicitis , diverticulitis , fever , follow-up after initial pancreas protocol , follow-up tumors other than hepatocellular carcinoma , general abdominal complaint , lower right quadrant tenderness , nausea & vomiting , non-complicated pancreatitis , pelvic inflammatory disease / PID , possible abdominal free air , post-op follow-up , small bowel obstruction , testicular mass , tubo-ovarian abscess / TOA , weight loss .
*