MR Brain DBS Localization No IVcon IMG15255
Machine Model: Aera, Avanto, Prisma, Skyra, Verio
Generated:
2025-03-19 16:01:26
1
2
3
4
5
Plane Axial Axial Axial Axial Axial
Sequence 3D T1 isotropic 3D Inverted T1 MPRAGE/FGATIR T2 TSE T2 FLAIR FS DTI
Timing --- --- --- --- ---
Thickness - Spacing 1 mm - mm 1 mm - mm 4 mm - 1 mm 4 mm - 1 mm 2 mm -
FOV 256mm 256mm approx. 200mm approx. 200mm 250mm
Special Instructions:
Take extra care to cover ENTIRE brain

Indications: No indications found.
#1,2
#3,4
#5
IF SCAN TIME IS LIMITED DUE TO PATIENT CONDITION OR IMPLANT CONDITIONS THE ORDER OF IMPORTANCE FOR SEQUENCES IS:
1 - AX 3D T1 MPRAGE 
2 - AX 3D FGATIR (Inverted MPRAGE)
3 - SAG 3D T2 FLAIR iso (or 2D FLAIR if using TxRx coil)
*USE 64CH COIL FOR PRE FUS PROCEDURE 
DTI 64dir (A>P/P>A) on PRISMA. 30dir(A>P) SKYRA