MR Angio Spinal Canal w/IVcon | IMG15196 | |
Machine Model: | HVN Skyra, NT Verio |
Generated:
2022-10-17 18:48:06
|
|
1 *
|
2
|
3
|
|
|
Plane | Sagittal | Sagittal | Sagittal Oblique | ||
Sequence | T1 TSE LFOV localizer | 3D T2 SPACE | 3D T1 MRA Hi-res | ||
Timing | --- | --- | Pre-Contrast | ||
Thickness - Spacing | 5 mm - 1 mm | 3 mm - 0 mm | 0.5 mm - 0 mm | ||
FOV | approx. 450mm | approx. 330mm | approx. 320mm |
4
|
|
5
|
6
|
7
|
|
Plane | Sagittal Oblique | Sagittal Oblique | Axial (upper) | Axial (lower) | |
Sequence | TWIST 4D MRA | 3D T1 MRA Hi-res | T2* MEDIC | T2* MEDIC | |
Timing | Start TWIST sequence and power injection at EXACTLY the same time | post-bolus delay determined by phase selection from TWIST images minutes seconds | --- | --- | |
Thickness - Spacing | 1.2 mm - 0 mm | 0.5 mm - 0 mm | 3 mm - 1 mm | 3 mm - 1 mm | |
FOV | approx. 320mm | approx. 320mm | approx. 180mm | approx. 180mm |
Special Instructions: |
|
* Cover from base of skull down for counting vertebral level |
Indications: No indications found. |